Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

iTwin Capture Modeler

Showing 124 of 163

Support WMS as basemap

Add WMS as basemap option.
7 months ago in iTwin Capture Modeler 0 Needs review

Potential matches (closest)

Improve user tie point measurement photo selection by adding additional photo option to show only closest potential matches by selection nearest automatic points near measurement and the photos they view these point. That would discard photos whic...
11 months ago in iTwin Capture Modeler 0 Needs review

Cesium converter

It is included in mesh export but if a client delivers a Cesium mesh, we cannot consume it as at the moment, Open Apps can only consume and attached 3SM and cannot show Cesium and no converters in iTC Modeler or Manage & Extract
7 months ago in iTwin Capture Modeler 0 Needs review

DSM production from Point clouds

Add option to produce 2.5D DSM from Point clouds. Now the option is greyed out if only Point cloud is imported. This would be useful if only less detailed aerial LIDAR is available. It could be still a reality mesh but utilizing all points and all...
4 months ago in iTwin Capture Modeler 0 Needs review

Save import Survey settings

Add the ability to save settings when adding survey points file (same structure of file in every project)
over 1 year ago in iTwin Capture Modeler 0 Needs review

Point cloud in 3D view

Ability to switch between RGB/Intensity/Classification view for point clouds in 3D display.
over 1 year ago in iTwin Capture Modeler 0 Needs review

Modeler Engine Monitor software

I would like to request some software that can monitor and manage all of the engines which are ready to do the job. Sometimes, I found the problem that Modeler Engine Center did not choose the best performance computer (some computer bought 2-3 ye...
over 1 year ago in iTwin Capture Modeler 0 Needs review

alpha channel for GeoTiff

Is it possible to have an alpha channel for GeoTiff output of orthophotos in iTwin Capture? This would be a very important development issue for us. An alpha feature in GeoTiff would greatly streamline our processes.
12 months ago in iTwin Capture Modeler 0 Needs review

GCPs default accuracy

Option to select default accuracy for newly created GCPs and also set it as checkpoint and type.
8 months ago in iTwin Capture Modeler 0 Needs review

Processing multispectral and thermal images

Ability to process images from multispectral and thermal cameras gives wider application of reality data. Infrared imaging is increasingly used for obtaining thermal maps, in particular of industrial installations, to quickly detect anomalies in p...
over 1 year ago in iTwin Capture Modeler 0 Needs review